BI-LEVEL NONINVASIVE VENTILATOR

DPAP20 Plus
  • Mode:CPAP, S, S/T. T
  • IPAP range:4 - 20cmH2O
  • EPAP range:4 - 20cmH2O
  • CPAP range:4 - 20cmH2O
  • I-trigger:Auto,1 to 3
  • E-trigger:Auto,1 to 3
  • Rise Time:100-600 msec
  • Breath rate:Adjustable 0 - 40
  • Noise Level:<30dB@ 10cmH2O
  • CPAP Ramp:0-60minutes.1 minute increment
  • Display Data:IPAP, EPAP,Vt, Vleak,l:E Ratio, BR, MV
  • Power failure
  • Mask Alarm
  • Apnea Alarm
  • High/Low Rate Alarm
  • Screens:2.8" TFT
  • Pressure bar graph
  • Data
  • Tube Length:1.8m, 2m
  • Dimensions:21X21X11cm
  • Weight:2.1kg
DPAP25 Plus
  • Mode:CPAP, S, S/T. T
  • IPAP range:4 - 25cmH2O
  • EPAP range:4 - 20cmH2O
  • CPAP range:4 - 20cmH2O
  • I-trigger:Auto,1 to 3
  • E-trigger:Auto,1 to 3
  • Rise Time:100-600 msec
  • Breath rate:Adjustable 0 - 40
  • Noise Level:<30dB@ 10cmH2O
  • CPAP Ramp:0-60minutes.1 minute increment
  • Display Data:IPAP, EPAP,Vt, Vleak,l:E Ratio, BR, MV
  • Power failure
  • Mask Alarm
  • Apnea Alarm
  • High/Low Rate Alarm
  • Screens:2.8" TFT
  • Pressure bar graph
  • Data
  • Tube Length:1.8m, 2m
  • Dimensions:21X21X11cm
  • Weight:2.1kg
DPAP25 Pro
  • Mode:CPAP, S, S/T. T
  • IPAP range:4 - 25cmH2O
  • EPAP range:4 - 20cmH2O
  • CPAP range:4 - 20cmH2O
  • I-trigger:Auto,1 to 6
  • E-trigger:Auto,1 to 6
  • Rise Time:100-600 msec
  • Breath rate:Adjustable 0 - 40
  • Noise Level:<30dB@ 10cmH2O
  • CPAP Ramp:0-60minutes.1 minute increment
  • Display Data:IPAP, EPAP,Vt, Vleak,l:E Ratio, BR, MV
  • Power failure
  • Mask Alarm
  • Apnea Alarm
  • low Minute Ventilation
  • High/Low Rate Alarm
  • Screens:2.8" TFT
  • Pressure bar graph
  • Data display
  • Waveform
  • Pressure curve
  • Flow rate curve
  • Volume curve
  • Tube Length:1.8m, 2m
  • Dimensions:21X21X11cm
  • Weight:2.1kg
DPAP 30 Pro
  • Mode:CPAP, S, S/T. T
  • IPAP range:4 - 30cmH2O
  • EPAP range:4 - 20cmH2O
  • CPAP range:4 - 20cmH2O
  • I-trigger:Auto,1 to 6
  • E-trigger:Auto,1 to 6
  • Rise Time:100-600 msec
  • Breath rate:Adjustable 0 - 40
  • Noise Level:<30dB@ 10cmH2O
  • CPAP Ramp:0-60minutes.1 minute increment
  • Display Data:IPAP, EPAP,Vt, Vleak,l:E Ratio, BR, MV
  • Power failure
  • Mask Alarm
  • Apnea Alarm
  • low Minute Ventilation
  • High/Low Rate Alarm
  • Screens:2.8" TFT
  • Pressure bar graph
  • Data display
  • Waveform
  • Pressure curve
  • Flow rate curve
  • Volume curve
  • Tube Length:1.8m, 2m
  • Dimensions:21X21X11cm
  • Weight:2.1kg